Green Tea aids with your body weight loss. It burns fat and boosts your metabolism rate naturally. It can help you burn up to seventy calories in just one day. That translates to seven pounds in one year. It increases the metabolism. The polyphenol found in works to intensify levels of fat oxidation and the rate at which your body turns food into calories.Prevents fatness by stopping the movement of glucose in fat cells.
Here are 12 Benefits of Green Tea you must read :

Important Safety Information To Consider When Applying Intensity Twin Stim III

By Cornelia Reyes


It is sensible to first have an understanding and the workings of InTENSity Twin Stim III before engaging on a conversation on the significant safety information to consider. If the information is not taken into consideration, the patient my suffer survivor effects which are dangerous. InTENSity Twin Stim III is an electric device which physicians use to help patients to relive pain. The device works by sending gentle electric currents to the muscles in the skin which is painful.

This article looks at some of the vital information to consider when using it. The first information is that it must not be controlled by any person who is not professional and qualified to handle it. It must be operated only by a licenced physician with the knowledge on how to use it.

It must not also be used on a pregnant woman since the inventors are yet to provide safety measures to ensure when using it on a pregnant woman. If it is used, it can lead to miscarriage of the pregnancy.

This is for the reason that the electric electrons are likely to cause breathing difficulty to the patient. It must also not be applied transthoracally as this may introduce some electric currents to the heart. As a result of the introduction of the electric current to the heart, the patient will suffer from cardiac arrhythmias.

The other important to note that power output of InTENSity Twin Stim III may be affected if it is used in the same place where there is microwave and shortwave therapy equipment. Therefore the physician should ensure that it is used in a place free from any interference from any equipment. The environment for its use is another thing to consider. The environment should be one which is free from moist such as the washrooms.

When the patient is connected to surgical equipment with high frequency, the device must never be used on their skin. This is for the reason that it is used, the patient is likely to suffer from burnt skin injuries caused by the electric current from the device. If it has to be used in the patient, the surgical equipment must be disconnected first or the frequency reduced.

It is also necessary to note that it is not recommended to be used on patients suffering from any heart disease on any skin are close to the heart. This is to prevent that the patient from suffering cardiac arrest. The physician using the device must ensure that the skin are is clean and dry.

Any area close to the heart must also be avoided. This is because if it is used in those areas, there is likelihood that the patient will suffer from cardiac arrest as it exposes ventricular fibrillation to various risk. Patient who are suffering from heart diseases must also refrain from using it. It is recommended that unbroken dry skin areas are the ones which are suitable for use. These forms part of the vital safety information to consider when applying InTENSity Twin Stim III.